ATM TILES RANGE:

TECHNICAL DATA ATM006 ATM012 ATM018 AMT036 ATM052 ATM065
Nominal evaporating capactity (at 0 mslm) l/h 600 1.200 1.800 3.600 5.200 6.500
Atomised production (@ 34% H2O) kg/h 1.410 2.830 4.240 8.490 12.260 15.320
Nominal installed heat output kcal/h 540.000 1.050.000 1.500.000 3.000.000 4.300.000 5.500.000
Air temperature at tower inlet °C 500÷600 500÷600 500÷600 500÷600 500÷600 500÷600
Outlet air temperature °C 60÷130 60÷130 60÷130 60÷130 60÷130 60÷130
Atomised powder temperature °C 40÷60 40÷60 40÷60 40÷60 40÷60 40÷60
Moisture atomised powder % 4÷7 4÷7 4÷7 4÷7 4÷7 4÷7
Specific heat consumption kcal/l H2O 750÷850 700÷850 700÷850 700÷850 700÷850 700÷850
Number of lances n. 3 6 7 9 10 12
Nozzles - maximum number with LANCE n. 6 12 14 18 20 24
Nozzles - maximum number with CORONA n. 6 12 15 20 28 32
Cyclone separators 1 1 1 2 2 2
Installed electrical power rating kW 14,0 22,5 35,5 63,5 90,0 125,0
TECHNICAL DATA ATM090 ATM110 ATM140 AMT180 ATM200 ATM250
Nominal evaporating capactity (at 0 mslm) l/h 9.000 11.000 14.000 18.000 20.000 25.000
Atomised production (@ 34% H2O) kg/h 21.210 25.930 33.00 42.430 47.140 58.930
Nominal installed heat output kcal/h 7.500.000 9.200.000 11.500.000 15.000.000 16.700.000 21.000.000
Air temperature at tower inlet °C 500÷600 500÷600 500÷600 500÷600 500÷600 500÷600
Outlet air temperature °C 60÷130 60÷130 60÷130 60÷130 60÷130 60÷130
Atomised powder temperature °C 40÷60 40÷60 40÷60 40÷60 40÷60 40÷60
Moisture atomised powder % 4÷7 4÷7 4÷7 4÷7 4÷7 4÷7
Specific heat consumption kcal/l H2O 700÷850 700÷850 700÷850 700÷850 700÷850 700÷850
Number of lances n. 12 13 14 18 18 24
Nozzles - maximum number with LANCE n. 24 26 28 36 36 48
Nozzles - maximum number with CORONA n. 32 40 48 - - -
Cyclone separators 2 4 4 4 4 6
Installed electrical power rating kW 150,5 182 230 355,5 355,5 407